OPERATION MANUAL KPS-50 BAR CODE LABEL PRINTING SCALE Twohong System Inc. INTRODUCTION THANK YOU VERY MUCH FOR YOUR CHOOSING A SpeedJet BAR CODE LABEL PRINTING SCALE,TYPE KPS-50. THIS WEIGHING SCALE HAS BEEN MANUFACTURED UNDER STRICT QUALITY CONTROL AND SHOULD GIVE YOU FULL SATISFACTION. HOWEVER, IF THE WEIGHING SCALE IS DAMAGED DURING TRANSIT, OR THERE ARE UNCLEAR POINTS IN THIS MANUAL, PLEASE CONTACT YOUR REPRESENTATIVE. PLEASE CONTACT THEM AS TO OPTIONAL FUNCTIONS,AS WELL. BE SURE TO KEEP THIS MANUAL FOR FUTURE REFERENCE. CONTENTS 1. OVERVIEW 2. SPECIFICATIONS 3. NOMENCLATURE 4. DESCRIPTION OF FRONT PANEL AND THE FUNCTIONS 5. INSTALLATION AND PREPARATION FOR OPERATION 5-1 SCALE SET UP A. GETTING THINGS READY B. PRECAUTIONS 5-2 MANUFACTURING DATE AND TIME INPUT A. TO INSTALL OR CHANGE MANUFACTURING DATE B. TO INSTALL OR CHANGE TIME 5-3 PROGRAMMING - MANAGEMENT FUNCTIONS A. INITIALIZING 5-4 PROGRAMMING LIBRARY A. SUMMARY B. LIBRARY PROGRAMMING PROCEDURE C. EDITING LIBRARY FILES 1) TO BEGIN LIBRARY FILE EDIT; 2) TO EDIT ONE WHOLE LINE 3) TO EDIT ONE WORD OR PHRASE AMONG ONE LINE 5-5 PROGRAMMING PLU FILES A. IMPORTANT TERMS B. PLU FILE PROGRAMMING PROCEDURE C. EDITING PLU FILES 1) PLU FILE EDIT PROCEDURE 2) TO EDIT PLU DATA 1) LIBRARY NUMBER 2) UNIT PRICE 3) FIXED PRICE 4) FIXED QUANTITY 5) TARE WEIGHT 6) SHELF LIFE 7) BAR CODE NUMBER 8) GROUP NUMBER D. TO STORE THE PLU DATA DURING NORMAL WEIGHING OPERATION. 6. OPERATION PROCEDURE 6-1 NORMAL OPERATION A. PLU NO. RECALL OPERATION B. TEMPORAL CHANGES OF THE STORED PLU DATA 1) UNIT PRICE CHANGE 2) FIXED PRICE CHANGE 3) FIXED WEIGHT CHANGE 4) TARE WEIGHT CHANGE 5) SHELF LIFE CHANGE 6) BAR CODE NUMBER CHANGE 7) LIBRARY NO. CHANGE 8) GROUP NUMBER CHANGE 6-2 KEY SWITCH OPERATION 1) UNIT PRICE,WEIGHT,PRICE LABEL ISSUANCE 2) FIXED PRICE LABEL 3) FIXED WEIGHT AND FIXED PRICE LABEL 4) UNIT PRICE, FIXED WEIGHT, TOTAL PRICE LABEL 5) FIXED PRICE BY COUNT ,TOTAL PRICE LABEL 6-3 SUB TOTAL LABEL ISSUANCE FOR CUSTOMER DEPOSIT AND CHANGE CLEARANCE CE A.CLEARING THE BALANCE OF DEPOSIT PAYMENT LABEL ISSUANCE B.CLEARING ALL THE TRANSACTION ONLY BY ONE SUB TOTAL LABEL ISSUANCE. 6-4 TEMPORAL STOP OF LABEL ISSUANCE 6-5 TARE WEIGHT SUBTRACTION A.TARE WEIGHT SUBTRACTION BY TARE KEY B.TARE WEIGHT SUBTRACTION BY DIGIT KEY C.TO RELEASE THE TARE WEIGHT : 6-6 VARIOUS CLEAR FUNCTION KEY A. TO DELETE ITEM NAME TEMPORALLY ON LABEL PRINTING B. TO DELETE BARCODE NO. TEMPORALLY ON LABEL PRINTING C. TO DELETE WEIGHT TEMPORALLY ON LABEL PRINTING D. TO DELETE UNIT PRICE TEMPORALLY ON LABEL PRINTING E. TO DELETE TOTAL PRICE TEMPORALLY ON LABEL PRINTING 7. RETRIEVING MANAGEMENT DATA 7-1 PRINT ALL ACCUMULATORS-SORTED BY PLU NO. 7-2 SUB TOTAL AND GRAND TOTAL LABEL ISSUANCE A. ITEM B. GROUP 7-3 DAILY TOTAL REPORT LABEL ISSUANCE 7-4 A.B.C. ANALYSIS 7-5 SALES ANALYSIS ON TIME CYCLE 8. LABEL SIZE, PRINTING CONTENT, PRINTING LOCATION A. LABEL SIZE, SHAPE B. LABEL CONTEXT,LETTER LOCATION C. LOADING LABEL D. ADJUSTING LABEL 10.ERROR MESSAGE 11.COMPUTER INTERFACE/ SCALE CONNECTION ------------------------------------------------------------------------------ 1. OVERVIEW THIS MANUAL PROVIDES A DESCRIPTION ABOUT THE FUNCTIONS AND HANDLING OF THIS SCALE AND RETRIEVE THE INFORMATION STORED IN THE SCALE. IT HAS BEEN DESIGNED TO MANAGE THE DATA PERFECTLY AND SEEK FOR THE ULTIMATE USABILITY. PLEASE READ CAREFULLY TO OBTAIN MAXIMUM UTILITY FROM IT. 2. SPECIFICATIONS DIMENSION : 452mm WIDTH X 420mm DEPTH X 539mm HEIGHT( MODEL KPS-50T) 452mm WIDTH X 420mm DEPTH X 150mm HEIGHT( MODEL KPS-50 ) WEIGHING SENSOR : STRAIN GAGE TYPE LOAD CELL WEIGHING CAPACITY : 6kg X 2g OR 15kg x 5g, DUAL RANGE ACCURACY: 1/3000 TARE RANGE : 10% OF SCALE FULL CAPACITY DISPLAY: MESSAGE AND PLU(ITEM NAME) DISPLAY 64 CHARACTERS IN LCD WEIGHT 5 DIGITS, UNIT PRICE 5 DIGITS, TOTAL PRICE 6 DIGITS DISPLAY(VFD) WEIGHT,UNIT PRICE, TOTAL PRICE GRAPHIC LCD MODULE : ITEM NAME POWER: 110, 220V AC +/- 10% ,50/60Hz PLU PRESETING CONTENTS: DIRECT PLU: 40 KEY (OPTION 88 KEYS) PLU MEMORY NO.:2250(OPTION3000) UNIT PRICE OR FIXED AMOUNT GROUP NO. TARE WEIGHT OR FIXED QUANTITY SHELF LIFE (3 DIGIT) BAR CODE NO. LIBRARY NO. LIBRALY PRESETING CONTENTS: LIBRARY NUMBER: 999 ITEM (OPTION 7999) WORD,SENTENCE,SYMBOL LETTERS OF ITEM NAME, SHOP NAME & ADDRESS, SHOP LICENCE ID NO., TEL. NO., INGREDIENTS. TARE : SINGLE KEY DEPRESSION OF T KEY AND KEYING IN DIGIT KEY. TOTAL: SUB TOTAL: CUSTOMER TRANSACTION TOTAL(M+,M-,MR) GRAND TOTAL( WEIGHT:8 DIGIT,TOTAL AMOUNT: 8 DIGITS) REPORT: ITEM,GROUP,TIME,ABC MONEY CHANGE: DEPOSIT AND BALANCE CALCULATION KIND OF LABEL ISSUSANCE: AUTOMATIC ISSUANCE MANUAL ISSUANCE KIND OF LABEL: NORMAL WEIGHING LABEL, FIXED AMOUNT LABEL, FIXED WEIGHT LABEL, FIXED UNIT PRICE- TOTAL PRICE LABEL, FIXED AMOUNT LABEL SUB TOTAL LABEL MONEY CHANGE LABEL(SUB TOTAL,PAYMENT,CHANGES,TOTAL) TOTAL RESET LABEL MODE; ITEM,WEIGHT,UNIT PRICE,TOTAL PRICE,BAR CODE. TAXATION REGISTER : AUTOMATICALLY TAX INCLUDING CALCULATION. LABEL ISSUANCE STOP FUNCTION: IN CASE OF NO NEED LABEL. LABEL PRINTING CONTENTS: ITEM (LARGE CHARACTER 16, SMALL CHARACTER 64) MANUFACTURING DATE; DAY, MONTH, YEAR EXPIRY DATE; DAY, MONTH, YEAR WEIGHT(5 DIGIT) UNIT PRICE( 5 DIGIT) TOTAL PRICE (6 DIGIT) GROUP( 2 DIGIT) TIME( 2 DIGIT) BAR CODE (13 DIGIT OR 8 DIGIT) ITEM NUMBER ADDRESS SHOP LICENCE ID NO. TEL. NO. PRICE OF NON-WEIGHED ITEM, INGREDIENT, SHELF LIFE, ADVERTISEMENT,MESSAGE . TAX IMPOSE, ETC. LABEL PRINTING TYPE ARRANGEMENT LABEL SIZE AND TYPE IS TO BE PRESETTED IN THE FUNCTION PROGRAMMING MODE. LABEL SIZE: WIDTH MAXIMUM 60 mm x VARIABLE LENGTH(MAXIMUM 122mm) PC INTERFACE: RS 232C AND RS485 DIRECT CONNECTION 3. NOMENCLATURE 4. DESCRIPTION OF FRONT PANNEL AND THE FUNCTIONS 4-1. KEY ARANGEMENT 4-2 NAMES OF EACH KEYS AND THEIR FUNCTIONS A) DIGIT KEYS <0>-<9> THIS IS USED TO ENTER THE VALUES FOR UNIT PRICE, WEIGHT,PRICE, QUANTITY, TARE ETC. DIGIT KEYS HAVE DUAL FUNCTIONS BY USING WITH < SHIFT KEY> 1) <0 KEY>: USED TO ENTER NUMBER 0. USED TO PRESET [CLOCK MODE] BY DEPRESSING WITH SHIFT KEY. 2) <1 KEY>: USED TO ENTER NUMBER 1. USED TO CLEAR ITEMS NAME BY DEPRESSING TOGETHER WITH . 3) <2 KEY>: USED TO ENTER NUMBER 2. USED TO PRESET THE MANUFACTURING DATE BY DEPRESSING WITH . 4) <3 KEY>: USED TO ENTER NUMBER 3. USED TO PRESET THE EXPIRY DATE BY DEPRESSING WITH IN PROGRAMMING PLU FILE. 5) <4 KEY>: USED TO ENTER NUMBER 4 USED TO CLEAR BAR CODE PRINTING MODE BY DEPRESSING WITH . 6) <5 KEY>: USED TO ENTER NUMBER 5 USED TO PRESET THE UNIT PRICE 1/2 lb BY DEPRESSING WITH USED TO SELECT CHINESE CHARACTER IN THE PROGRAMMING LIBRARY. 7) <6 KEY>: USED TO ENTER NUMBER 6. USED TO PRESET THE UNIT PRICE 1/4 lb BY DEPRESSING WITH . USED TO SELECT ENGLISH CHARACTER IN THE PROGRAMMING LIBRARY. 8) <7 KEY>: USED TO ENTER NUMBER 7. USED TO CLEAR THE WEIGHT PRINTING ON LABEL BY DEPRESSING WITH . GRAPHIC MODE IN THE PROGRAMMING LIBRARY 9) <8 KEY>: USED TO ENTER NUMBER 8 USED TO CLEAR UNIT PRICE PRINTING ON LABEL BY DEPRESSING WITH . 10)<9 KEY>: USED TO ENTER NUMBER 9 USED TO CLEAR THE TOTAL PRICE PRINTING ON LABEL BY DEPRESSING WITH . 11): USED TO OBTAIN THE SECONDARY FUNCTION OF THE KEYS. USED TO READ THE CONTENTS OF TRANSACTION AFTER CALCULATING SUB TOTAL BY . 12) : USED TO CLEAR ENTERING NUMBERS SUCH AS UNIT PRICE, TARE, ETC. USED TO CLEAR THE DATA OF SUB TOTAL, GRAND TOTAL. USED TO TRANSFER THE PROGRAMMING MODE FROM WEIGHING MODE BY DEPRESSING WITH . 13) :USED TO PRESET FIXED PRICE. USED TO PRESET TAX RATE INPUT WITH SFT KEY. USED TO MOVE THE CURSOR TO THE FIRST DIGIT IN THE PROGRAMMING LIBRARY MODE. 14) :USED TO DEDUCT FROM SUB TOTAL AND GRAND TOTAL. USED TO CALL THE GROUP MODE BY DPRESSING WITH . USED TO CALL THE GROUP MODE IN THE PROGRAMMING PLU MODE. USED TO MOVE THE CURSER TO THE ONE UPPER LINE IN THE PROGRAMMING LIBRARY MODE. 15) : USED TO ADD TO THE SUB TOTAL AND GRAND TOTAL USED TO RECALL THE GRAND TOTAL BY DEPRESSING WITH . USED TO PRESET LIBRARY NUMBER IN THE PROGRAMMING LIBRARY MODE. 16) :USED TO TURN ON POWER AND RESET ZERO. USED TO DO SYSTEM RESET BY DEPRESSING WITH . USED TO SELECT PROGRAMMING FUNCTION MODE. 17) : USED TO SET UNIT PRICE USED TO PRESET UNIT PRICE CLEAR MODE AFTER WEIGHING BY DEPRESSING WITH . USED TO MOVE THE CURSOR ONE COLUMN TO THE LEFT SIDE IN THE PROGRAMMING LIBRARY MODE. 18) :USED TO SUBTRACT TARE WEIGHT. USED TO INPUT TARING MODE BY DEPRESSING WITH . USED TO MOVE THE CURSO R ONE STEP TO THE RIGHT SIDE COLUMN IN THE PROGRAMMING LIBRARY MODE. 19) : USED TO ENTER THE PLU NUMBER. USED TO ENTER THE DATA SUCH AS UNIT PRICE, ETC. BY DEPRESSING WITH THE . 20) : USED TO RECALL THE SUB TOTAL. USED TO TRANSFER THE PROGRAMMING MODE TO BAR CODE MODE BY DEPRESSING WITH . USED TO MOVE THE CURSER ONE LINE BELOW IN THE PROGRAMMING LIBRARY MODE. 21) : USED TO ISSUE LABEL OF THE FIXED QUANTITY BY COUNT AND TOTAL PRICE. USED TO CHANGE THE FIXED QUANTITY MODE BY DEPRESSING WITH . USED TO ENTER THE FIXED QUANTITY IN THE PROGRAMMING PLU MODE. USED TO MAKE ONE MORE LINE IN THE PROGRAMMING LIBRARY MODE. 22) : USED TO ISSUE LABEL. USED TO ADD PLUS FUNCTION. USED TO STOP LABEL ISSUANCE BY DEPRESSING WITH . USED TO STORE THE DATAS IN PROGRAMMING MODE. 23) :USED TO CHANGE THE LABEL ISSUANCE MODE FROM AUTOMATIC LABEL ISSUANCE MODE TO MANUAL LABEL ISSUANCE MODE OR VICE VERSA. USED TO FEED THE LABEL BY DEPRESSING WITH . USED TO TRANSFER THE PROGRAMMING MODE TO LIBRARY PROGRAMMING MODE. 24) <4X10 KEYPAD>: USED TO RECALL THE DIRECT PLU NUMBER. USED TO MAKE LIBRARY CHARACTER IN THE LIBRARY PROGRAMMING MODE. 5. INSTALLATION AND PREPARATION FOR OPERATION 5-1 SCALE SET UP A. GETTING THINGS READY 1) PLACE THE SCALE ON A STIFF TABLE. LEVEL THE SCALE BY TURNING THE ADJUSTING LEGS SO THAT THE LEVEL INDICATOR MAY SETTLE AT THE CENTER OF THE CIRCLE. 2) MAKE SURE TO INSERT THE PLUG ON THE POWER CABLE INTO THE OUTLET. 3) DEPRESS TO TURN ON THE DISPLAY ,BY WHICH THE DISPLAY WILL FLASH FOUR TIMES TO DISPLAY "0". 4) CHECK LABEL SIZE( WIDTH, LENGTH) 5) SET THE LABEL TO THE INSERTING GUIDE 6) CHECK PROGRAMMING MODE SETTING KEY 7) READ OPERATION MANUAL ENOUGH CAUTION: BE SURE NO MATERIAL ON THE PLATTER WHEN DEPRESSING "ON/Z" KEY. B. PRECAUTIONS 1) INSTALLATION PLACE: IN CASE OF EXCCESIVE MOISTURE,DUST,SUN LIGHT,HEAT,VIBRATION IT MAY CAUSES TROUBLE AND MISOPERATION. 2) POWER SOURCE: AVOID FREQUENT SURGE VOLT VARIATION 3) STORAGE OF LABEL KEEP LABEL IN COOL AND DRY,CLEAN PLACE. 4) PROGRAMM LOCK KEY: KEEP RIGHT PLACE. PLEASE READ MANUAL NOT TO ERASE DATA BY MISTAKE. 5-2 MANUFACTURING DATE AND TIME INPUT A. TO PRESET OR CHANGE MANUFACTURING DATE 1) DEPRESS TOGETHER WITH SHIFT KEY .....P dAtE MODE IS DISPLAYED ON THE WINDOW. 2) TO CHANGE YEAR,MONTH,DATE: IF THE USER WANT TO CHANGE YEAR MONTH DATE, DEPRESS FIRST. 3) KEY IN DIGIT NUMBER AS 95.04.30, YEAR, MONTH, DATE .....DIGIT IS DISPLAYED ON WINDOW NOTE: TO SELECT THE ORDER OF YEAR, MONTH, DATE PLEASE REFER THE FUNCTION PROGRAMMING. 4) DEPRESS (UNIT PRICE KEY) ..... ALL DATA STORED AND THE SCALE BECOMES READY FOR WEIGHING OPERATION B. TO PRESET OR CHANGE TIME 1) DEPRESS TOGETHER WITH SHIFT KEY ..... DATE MODE IS DISPLAYED ON WINDOW. 2) TO CHANGE THE TIME: IF THE USER WANT TO CHANGE TIME ,MINUTE, SECOND, DEPRESS FIRST. 3) KEY IN DIGIT NUMBER,TIME,MINUTE,SECOND ..... DIGIT IS DISPLAYED ON WINDOW. 4) DEPRESS THE .....ALL DATA IS STORED AND THE SCALE BECOMES READY FOR WEIGHING OPERATION. 5-3 PROGRAMMING - MANAGEMENT FUNCTIONS A. INITIALIZING INITIALIZATION IS THE METHOD PROVIDED TO COMPLETELY ERASE THE SCALE MEMORY. BEFORE BEGINNING TO PROGRAMM A NEW SCALE IT MUST FIRST BE INITIALIZED TO CLEAR THE MEMORY OF ANY PREVIOUS OR ERRONEOUS DATA. ONCE PLU FILES HAVE BEEN PROGRAMMED, THIS STEP SHOULD NOT BE REPEATED UNLESS YOU INTEND TO ERASE ALL OF THE INFORMATION CURRENTLY PROGRAMMED IN THE SCALE. THERE ARE THREE DIFFERENT PROGRAMMING MODE. ONE IS A PLU PROGRAMMING MODE. SECOND IS A LIBRARY PROGRAMMING MODE. THIRD IS A SCALE FUNCTION PROGRAMMING MODE. 1) P MODE P IS ABREBIATION OF PLU( PRICE LOOK UP) FILE. THIS MODE IS USED TO PRESET PLU NO.,DATA INPUT, DATA EDITING, DATA CHECKING. THIS [P MODE] SHALL BE CALLED AS [ PROG.PLU MODE]. 2) L MODE L IS ABREBIATION OF LIBRARY. THIS MODE IS USED TO PRESET LIBRARY NO., LIBRARY DATA EDITING, LIBRARY DATA CHECKING,WHICH CONTAINS ITEM NAME,SENTENCE, SYMBOL. THIS [L MODE] SHALL BE CALLED AS [PROG. LIB. MODE]. 3) F MODE F IS ABREBIATION OF FUNCTION. THIS MODE IS USED TO PRESET THE SCALE FUNCTION ,CHANGE AND CHECK THE FUNCTION OF THE SCALE BY THE MANAGER WITHIN THE LIMITED RANGE. CAUTION: BE CAREFUL WITH PROGRAMMING OPERATION. FAULT OPERATION MAY ERASE THE STORED DATA. ESPECIALLY FUNCTION PROGRAMMING MODE SHOULD BE HANDLED WITH TOP SAFE SECURITY . 5-4 PROGRAMMING LIBRARY A. SUMMARY 1) ITEM NAME,INGREDIENT,ADRESS ETC.SHOULD BE ENTERED BY THIS LIBRARY PROGRAMMING MODE. THIS LIBRARY PROGRAMMING IS VERY IMPORTANT BECAUSE ALL DATAS WHICH IS NECCESSARY FOR LABEL PRINTING EXCEPT THE NORMAL WEIGHING DATAS SUCH AS WEIGHT, UNIT PRICE. PRICE, MANUFACTURING DATE,TIME,SHELF LIFE,ETC SHOULD BE PROVIDED IN THIS LIBRARY PROGRAMMING. 2) BY DEPRESSING THE DURING THE PROG. LIB. MODE, THE LIBRARY NUMBER IS INCREASED ONE BY ONE AND BECOME THE NEXT NUMBER. BY DEPRESSING TOGETHER WITH , THE LIBRARY NUMBER IS DECREASED ONE BY ONE AND BECOME THE PREVIOUS NUMBER. 3) <10 X 4 SCALE KEYPAD IS USED TO ENTER THE CHARACTERS AND SYMBOLES TO MAKE ITEM NAME AND OTHER DATAS. NOTE: THE USER CAN USE P.C. KEYBOARD BY OPTION. USE A SEPERATE CHARACTER KEY PAD WHICH IS SUPPLIED FROM MAKER 4) WHEN LIBRARY PROGRAMMING MODE IS BEGUN,THE LINE NUMBER AND THE CURSER NUMBER IS DISPLAYED ON UNIT PRICE WINDOW. THE CURSER IS INCREASED BY TWO DIGIT NUMBER AT ONE TIME TO FORM ONE CHARACTER OR SYMBOL IN MAKING THE LIBRARY BY EVERY DEPRESSING <4X10 SCALE KEY PAD>. IT MEANS THE CURSER WHICH MAKES THE CHARACTER OF LIBRARY IS COMPRISED OF TWO DIGIT NUMBER. NOTE: KPS-50T SHOW THE LETTERS ON LCD SCREEN. THIS IS GREATLY CONVENIENT TO CONFIRM THE LIBRALY. 5) DEPRESS TO STORE THE CHARACTER OR SYMBOL IN LIBRARY NUMBER AFTER DATA ENTERING. NOTE: AFTER DEPRESSING FOR STORING DATAS, REPEAT STEPS 1 THROUGH 5 FOR FURTHER CHANGES. B. LIBRARY PROGRAMMING PROCEDURE 1) PLACE [KEY LOCK] TO THE PROGRAM POSITION .....[ProG] IS DISPLAYED ON THE [WEIGHT WINDOW]. 2) DEPRESS .....[L OOO] IS DISPLAYED ON THE [WEIGHT WINDOW]. 3) ENTER THE DESIRED LIBRARY NUMBER .....[L OOOO] IS REPLACED WITH ENTERING LIBRARY NUMBER SUCH AS [L 1234]. NOTE: LIBRARY NUMBER CAN BE ENTERED BY DEPRESSING WHICH MAKE THE LIBRARY NUMBER INCREASE ONE BY ONE, OR BY DEPRESSING TOGETHER WITH THE WHICH MAKE THE LIBRARY NUMBER DECREASE ONE AFTER ONE. 4) DEPRESS< PRT KEY> ..... LINE NUMBER AND CURSER NUMBER IS DISPLAYED ON UNIT PRICE WINDOW SUCH AS 1-01. NOTE:[ L OOOO] [1 - 01] SHOWS THAT THE MODE IS READY FOR ENTERING THE ITEM NAME AND [OOOO] INDICATES THE LIBRARY NUMBER. LEFT [1] INDICATES [LINE NUMBER] AND [01] INDICATES THE CURSER NUMBER. 5) INPUT THE CODE NUMBER OF THE CHARACTER AND THE SYMBOL BY USING (4X10) KEY PAD ON FRONT PANNEL. .....THE CURSER NUMBER IS INCREASED BY ONE DIGIT WHENEVER THE CODE NUMBER IS ENTERED AND THE ENTERED NUMBER IS DISPLAYED ON THE PRICE WINDOW IN ORDER. NOTE:* THE CURSER NUMBER INDICATES THE AVAILABLE SPACE THAT THE CODE NUMBER TO BE ENTERED. THE MAXIMUM CUSRSER NUMBER IS 99. THIS MEANS THE 49 CHARACTER CAN BE ENTERED IN ONE LINE. * THE CODE NUMBER IS DISPLAYED ON THE PRICE WINDOW FROM THE LEFT TO THE RIGHT SIDE ON THE PRICE WINDOW. THE MAXIMUM NUMBER WHICH IS DISPLAYED ON THE WINDOW IS LIMITED BY 5 DIGIT. THEREFORE THE LAST NUMBER OVER 5 DIGITS IS REMAINED AT THE RIGHT SIDE OF PRICE WINDOW AND THE MOST LEFT SIDE OF THE CODE NUMBER IS HIDDEN ONE BY ONE TO THE LEFT SIDE OF THE PRICE WINDOW. * ERASE EVERY PREVIOUS ONE DIGIT CODE NUMBER TO AMEND BY DEPRESSING AT ONE TIME. * ANY ITEM NAME CAN BE ENTERED BY DEPESSING ,IF AND WHEN THE CODE NUMBERS ARE PROVIDED IN ADVANCE. 6) DEPRESS [ 2-01] SIGN APPEARED ON WINDOW. THIS MEAN THE LINE IS MOVED TO THE SECOND RAW AND THE CURSER BEGIN FROM THE START. NOTE:* TO MOVE THE LINE AT FIRST TIME, DEPRESS ABSOLUTELY. (UNDER ARROW) CAN NOT MOVE THE LINE WHEN IT START AT FIRST TIME. * WHEN EDITING, BE CAREFUL WITH CARRYING THE CURSER NOT TO ERASE THE DATA HIDDEN IN BACK MEMORY. * THE CURSER CAN BE MOVED TO THE LAST OF THE LINE BY DEPRESSING TARE KEY( RIGH SIDE ARROW) TOGETHER WITH . * THE CURSER CAN BE MOVED TO THE FIRST OF THE LINE BY DEPRESSING THE (LEFT SIDE ARROW KEY). 7) DEPRESS< PRT KEY> ......ALL DATA BLINKED AND THE PRICE WINDOW IS BLACKEN. NOW ONE ITEM NAME IS STORED IN MEMORY. NOTE: * BY DEPRESSING ONE MORE TIME, THE LINE IS DISPLAYED FROM NO. 1 LINE ON THE PRICE WINDOW. BY MOVING THE CURSER WITH THE ARROW KEY, THE DATA CAN BE CONFIRMED AND AMENDED. BE SURE TO DEPRESS AGAIN AFTER AMENDING ABSOLUTELY TO STORE THE AMEND DATA IN MEMORY. 8) DEPRESS ......THE NEXT LIBRARY NO.WILL BE SHOWN IN THE WINDOW. 9) REPEAT STEPS 1 THROUGH 8 FOR FURTHER CHANGES. C. EDITING LIBRARY FILES IF THE USER WANT TO EDIT THE LIBRARY FILE, THE SAME PROCEDURE OF LIBRARY PROGRAMMING WILL BE REPEATED. 1) TO BEGIN LIBRARY FILE EDIT; (1) PLACE KEY LOCK SWICTH TO THE" PROG MODE" (2) DEPRESS (3) ENTER THE LIBRARY NUMBER(ITEM NAME NUMBER) AND DEPRESS . .....1-01( LINE NUMBER AND CURSER NUMBER) IS DISPLAYED ON WEIGHT WINDOW AND 5 DIGIT NUMBER IS DISPLAYED ON PRICE WINDOW. 2) TO EDIT ONE WHOLE LINE (1) SEARCH THE DESIRED LINE TO EDIT BY USING UP AND DOWN ARROW KEY. MOVES LINE DOWNWARD AND MOVES LINE UPWARD. THE LINE NUMBER IS TO BE CHANGED ACCORDING TO THE COMPRISING LINE. (2) DEPRESS (RIGHT SIDE ARROW KEY) TOGETHER WITH . ......THE CURSER IS TO BE LOCATED AT THE MOST RIGHT END OF THE LINE. (3) DEPRESS ...... THE LAST CODE NUMBER AT RIGHT SIDE IS ERASED ONE BY ONE BY EVERY EACH DEPRESSING , INDICATING THE CURSER NUMBER DECREASED. NOTE: BY DEPRESSING , CONFIRM THE REMAINED DATA ON THE LINE. IF THE CURSER NUMBER IS NOT MOVED ANY LONGER, THE STORED CODE NUMBER IS ENTIRELY ERASED. (4) INPUT NEW ITEM CODE NUMBER USING BY OR . ......THE CODE NUMBER IS DISPLAYED ON THE WEIGHT WINDOW ,SHOWING THE CURSER NUMBER INCREASED ONE BY ONE. (5) ENTER ......ALL DATA BLINKED AND STORED. (6) THUS ONE LINE WHICH CONTAINS ONE ITEM NAME OR OTHER SENTENC IS FINISHED TO EDIT BUT THE OTHER LINE REMAINED WITHOUT EDITING IS EXISTED WITHOUT CHANGING. IF THE USER WANT EDIT SEVERAL LINE AT ONE TIME, REPEATE STEP 1 THROUGH 5 FOR FURTHER CHANGES. 3) TO EDIT ONE WORD OR PHRASE AMONG ONE LINE (1) SEARCH THE DESIRED LINE TO EDIT BY DEPRESSING AND MOVING KEY. * IS USED TO MOVE THE CURSER ONE LINE DOWN, INCREASING THE LINE NUMBER ONE BY ONE. * IS USED TO MOVE THE CURSER ONE LINE UPWARD DECREASING THE LINE NUMBER ONE BY ONE. (2) DEPRESS .....THE CURSER IS MOVED TO THE FIRST BEGINNING OF THE LINE. (3) DEPRESS TOGETHER WITH .....THE CURSER IS MOVED TO THE LAST END OF THE LINE. (4) SEARCH THE DESIRED WORD TO EDIT BY DEPRESSING AND MOVING KEY. * IS USED TO MOVE THE CURSER TO THE RIGHT SIDE OF THE COLUMN, INCREASING THE CURSER NUMBER ONE BY ONE. * IS USED TO MOVE THE CURSER TO THE LEFT COLUMN, DECREASING THE CURSER NUMBER ONE BY ONE. (5) FIX THE CURSER JUST BEHIND TO THE DESIRED CODE NUMBER TO EDIT., (6) DEPRESS TO ERASE THE CODE NUMBER TO BE AMENDED. .....THE CODE NUMBER TO EDIT IS ERASED ONE BY ONE WHENEVER EVERY DEPRESSING THE , DECREASING THE CURSER NUMBER ONE BY ONE. (7) INPUT A NEW CODE NUMBEWR ..... NEW DATA CODE NUMBER IS DISPLAYED ON PRICE WINDOW,SHOWING A CURSER NUMBER INCREASED WHENEVER THE NEW CODE NUMBER IS ENTERED (8) DEPRESS TO STORE THE DATA. ...... ALL DATA IS BLINKED AND STORED. NOTE: REPEAT STEP 1 THROUGH 8 TO CHANGE FURTHER. 5-5 PROGRAMMING PLU FILES A. IMPORTANT TERMS THE PLU FILE IS A USER PROGRAMMED RECORD PERTINENT TO EACH ITEM TO BE WEIGHED (AND /OR LABELED). ONCE PROGRAMMED INTO THE SCALES THE FILE IS RETRIEVED BY KEYING IN THE DESIRED ITEM PLU NUMBER. EACH PLU FILE CONSIST OF: [PLU NUMBER]; THIS IS THE I.D. NUMBER USED TO RECALL THE PLU FILE. ANY NUMBER FROM 1-999 MAY BE ASSIGNED,IN ANY ORDER. [LIBRARY NUMBER]; THIS IS THE I.D. NUMBER USED TO RECALL THE LIBRARY FILE IN WHICH THE ITEM NAME AND OTHER DESCRIPTIONS ARE PROGRAMMED. THE USER SHOULD USE THE ITEM NAME VIA LIBRARY NUMBER IN PLU FILE PROGRAMMING. [UNIT PRICE] OR [ FIXED PRICE]; THE ITEMS UNIT PRICE (PER 1 lb, PER 1/4,PER 1/2 lb, or BY COUNT) 5 DIGIT MAXIMUM,WITH OR WITHOUT FRACTIONAL PRICE. [BAR CODE NO.]; THIS IS A USER ASSIGNED "9" OR "13" DIGIT NUMBER WHICH WILL BE INCODED IN THE BAR CODE SYMBOLE. WHEN THE SYMBOL IS SCANNED THIS NUMBER IDENTIFIES THE ITEM TO THE POS SYSTEM. [GROUP]; THIS IS A USER ASSIGNED NUMBER(1-99) WHICH ALLOWS THE USER TO PULL COMBINED TOTALS FOR A GROUP OF PLU'S ASSIGNED THE SAME "GROUP" NUMBER. [TARE] OR [FIXED WEIGHT] ; THE WEIGHT OF CONTAINER USED TO PACKAGE THIS ITEM. THE WEIGHT FIXED FOR A GIVEN COMMODITY. [SHELF LIFE]; THE USER MAY ENTER 3 DIGIT NUMBER "0" THROUGH "365" DAYS THIS NUMBER CAN REPRESENT THE NUMBER OF DAYS (LIFE) OF A GIVEN COMMODITY OR ITS SELL BY DATE. 3 DIGIT DAYS CAN BE PROGRAMMED. THIS NUMBER IS ADDED TO THE CURRENT DATE PROGRAMMED IN THE SCALE AND WILL BE PRINTED OUT IN THE DATE FIELD OF LABEL. B. PLU FILE PROGRAMMING PROCEDURE PREPARE A LIST OF ALL COMMODITIES TO BE PROGRAMMED. THIS LIST SHOULD CONTAIN THE FOLLOWING INFORMATION FOR EACH COMMODITY: 1) PLACE KEYLOCK SWITCH TO "PROG" POSITION. ....."PROG" SIGN DISPLAYED ON WEIGHT WINDOW. AND OTHER DISPLAY BLANK OUT. 2) DEPRESS ......P X X X" SIGN APPEARED ON THE WEIGHT WINDOW INSTEAD OF " PROG". ..... " PROG.PLU MODE" BEGINS 3) KEYING IN DIGIT PLU NUMBER .....PLU NUMBER IS DISPLAYED ON THE WINDOW. 4) DEPRESS ..... PLU NUMBER IS ENTERED AND PROGRAMMING FUNCTION IS AUTOMATICALY ADVANCED TO THE LIBRARY NUMBER INPUT MODE. .....SIGN "LIB"IS DISPLAYED ON THE UNIT PRICE WINDOW. 5) KEYING IN LIBRARY NUMBER .....LIBRARY NUMBER DISPLAYED ON PRICE WINDOW. NOTE * THE ITEM NAME AND OTHER DATAS SHOULD BE ENTERED VIA LIBRARY NUMBER PRORAMMED IN LIBRARY FILE. 6) DEPRESS .....LIBRARY NUMBER ENTERED. AND PROGRAMMING FUNCTION IS AUTOMATICCALY ADVANCED TO UNIT PRICE MODE. NOTE: THE FIXED PRICE CAN BE ENTERED BY DEPRESSING "FIXED PRICE KEY" INSTEAD OF ENTERING UNIT PRICE. 7) KEYING IN UNIT PRICE OR FIXED PRICE BY DIGIT KEY ....."UNIT PRICE OR FIXED PRICE" IS DISPLAYED ON WINDOW. NOTE: THE UNIT PRICE AND FIXED PRICE MODE IS OPTIONAL. 8) DEPRESS ...... UNIT PRICE OR FIXED PRICE IS ENTERED AND PROGRAMMING FUCNTION IS AUTOMATICALLY ADVANCED TO THE BAR CODE ENTERING MODE. NOTE:IF THE USER NEED NOT TO INPUT BAR CODE NUMBER, PRESS TO ADVANCE THE PROGRAMMING MODE NEXT. 9) KEYING IN BAR CODE NUMBER ......BAR CODE NUMBER IS DISPLAYED ON WINDOW. 10) DEPRESS ..... BAR CODE NUMBER ENTERED AND PROGRAMMING FUNCTION IS AUTOMATICALY ADVANCED TO " GROUP ENTERING MODE". 11) KEYING IN GROUP NUMBER ......GROUP NUMBER IS DISPLAYED ON WINDOW 12) DEPRESS ..... GROUP NUMBER ENTERED AND PROGRAMMING FUNCTION IS AUTOMATICCALY ADVANCED TO TARE WEIGHT ENTERING MODE . NOTE: AT THIS PROCEDURE, IF THE USER WANT TO ENTER "FIXED QUANTITY ",PRESS "X KEY" TO CHANGE THE PROGRAMMING MODE TO" FIXED QUANTITY MODE. 13) ENTER TARE WEIGHT ......TARE WEIGHT DISPLAYED ON WINDOW. NOTE: REFER TARE ENETRING PROCEDURE IN DETAIL. THE TARE AND FIXED QUANTITY MODE IS ALSO OPTIONAL. 14) DEPRESS .....TARE WEIGHT ENTERED. AND PROGRAMMING FUNCTION IS AUTOMATICCALY ADVANCED TO SHELF LIFE MODE. 15) ENTER SHELF LIFE DAYS ..... SHELF LIFE DAYS DISPLAYED ON WINDOW. 16) DEPRESS ..... THE SHELF LIFE IS ENTERED. AND PROGRAMMING FUNCTION IS AUTOMATICCALY ADVANCED TO "LIBRARY MODE".WHICH IS DISPLAYED AT THE FIRST STEP OF PLU PROGRAMMING. NOTE: THE SHELF LIFE IS AUTOMATICALLY CALCULATED FROM THE MANUFACTURING DATE AND PRINTED ON THE LABEL AT THE DESIGNATED PLACE ON THE LABEL. 17) IN THIS WAY, ONE PLU NUMBER IS FINISHED TO STORE THE DATAS. THE USER CAN CONFIRM THE DATAS BY DEPRESSING THE ONE BY ONE. THE DATAS ARE RETRIEVED TURN BY TURN. IF THE USER WANT TO CHANGE DATA IN WHICH THE PROGRAMMING DATA IS STORED, DEPRESS UNTIL THE DESIRED PROGRAMMED DATA IS RETRIEVED, AND AMEND OR CHANGE THE DATAS ACCORDING TO THE EXPLAINED PROCEDURE AS ABOVE. THIS CYCLE IS TURN AND TURN UNTIL THE IS DEPRESSED. 18) DEPRESS< PLU KEY> TO PROGRAMM ANOTHER PLU NUMBER CONTINUOUSLY. ......PROG. PLU MODE IS DISPLAYED ON WINDOW. ..... THE NEXT PLU NUMBER IS AUTOMATICALY DISPLAYED ON WINDOW. NOTE: THE PROGRAMMING CYCLE IS ROUND AND ROUND FROM THE PROGRAMMING PROCEDURE NO.1 TO NO.18 AS EXPLAINED AS ABOVE UNTIL THE USER FINISH TO STORE ALL ITEMS AND DATAS BY DEPRESSING . NOTE: WHILE THE PLU PROGRAMMING PROCEDURE IS BEING PROCEEDED, THE USER CAN RECALL THE DESIRED PLU DATA MODE TO EDIT THE DATA BY DEPRESSING THE ASSIGNED KEY. REFER THE ASSIGNED KEY TO THE PLU EDIT 8-2. CAUTION: BE CAREFUL NOT TO DEPRESS OTHER NORMAL WEIGHING OPERATION MODE KEY AFTER ENTERING PLU DATA WITHOUT DEPRESSING FINALLY. IT MAY CLEAR THE DATA INPUT BEFORE. C. EDITING PLU FILES TO EDIT THE PLU FILE,IT IS POSSIBLE TO CHANGE THE PLU PROGRAMMING MODE BY THE KEYPAD.WHEN THE NEW DATA IS ENTERED,THE DATA IS STORED AUTOMATICALLY BY THE DEPRESSING THE NEXT PLU PROGRAMMING MODE IN STEAD OF DEPRESSING . 1) PLU FILE EDIT PROCEDURE A. PLACE KEY LOCK TO THE PROGRAMMING POSITION. B. DEPRESS THE C. INPUT THE PLU NUMBER. D. RECALL THE DESIRED PLU PROGRAMMING MODE BY KEYPAD NOTE: PLU PROGRAMMING MODE CAN BE RECALLED DIRECTLY BY THE INSTEAD OF DEPRESSING SUCCESIVELY THE , WHEREVER THE PROGRAMMING MODE IS LOCATED . WHEN PLU PROGRAMMING IS GOING ON ,PROCEDURE A. B. C. CAN BE SKIPPED. 2) PLU DATA EDIT A. LIBRARY NUMBER EDIT (1) DEPRESS ..........LIBRARY NO. MODE RECALLED (2) INPUT THE DESIRED LIBRARY NUMBER. B. UNIT PRICE EDIT (1) DEPRESS ..UNIT PRICE MODE RECALLED (2) INPUT THE DESIRED DIGIT NUMBER. C. FIXED PRICE EDIT (1) DEPRESS ..FIXED PRICE MODE RECALLED (2) INPUT THE DESIRED DIGIT NUMBER. D. GROUP NUMBER EDIT (1) DEPRESS ...........GROUP MODE RECALLED (2) INPUT THE DESIRED DIGIT NUMBER. E. TARE WEIGHT EDIT (1) DEPRESS ..........TARE WEIGHT MODE RECALLED (2) INPUT THE DESIRED DIGIT NUMBER. F. BAR CODE NUMBER EDIT (1) DEPRESS ............BAR CODE NUMBER MODE RECALLED (2) INPUT THE DESIRED DIGIT NUMBER. G. FIXED QUANTITY EDIT (1) DEPRESS .............FIXED QUANTITY MODE RECALLED (2) INPUT THE DESIRED DIGIT NUMBER. H. SHELF LIFE EDIT (1) DEPRESS TOGETHER WITH . ......SHELF LIFE MODE RECALLED. (2) INPUT THE DESIRED EXPIRY DATE. NOTE:IN THIS DATA EDITING PROCEDURE,THE DATAS IS AUTOMATICALY STORED ONLY BY DEPRESSING THE NEXT< MODE KEY> WITHOUT DEPRESSING . D. TO STORE THE PLU DATA DURING NORMAL WEIGHING OPERATION. THE PLU DATAS EXCEPT THE LIBRARY NUMBER SUCH AS UNIT PRICE, FIXED PRICE, GROUP NUMBER, FIXED QUANTITY,TARE WEIGHT, AND BAR CODE NUMBER, SHELF LIFE CAN BE EASILY CHANGED WHILE THE SCALE IS OPERATING IN NORMAL WEIGHING MODE. 1) DEPRESS WHILE THE SCALE OPERATING 2) ENTER THE DESIRED PLU NUMBER TO CHANGE DATAS 3) DEPRESS EACH KEYPAD TO RECALL DIRECTLY PLU DATA PROGRAMMING MODE. UNIT PRICE KEY..... UNIT PRICE MODE FIXED KEY........... FIXED PRICE MODE M-KEY................GROUP MODE TARE KEY.............TARE WEIGHT MODE MR KEY...............BAR CDODE NUMBER MODE X KEY................FIXED QUANTITY MODE 4) ENTER NEW DATA 5) PRESS PLU KEY WITH SHIFT KEY .. ALL DATA BLIKED AND NEW DATA ENTERED E. SUCCESIVE PLU GROUP NUMBER ENTERING 1) PRESS< PRT KEY> AFTER ENTERING PLU NUMBER AND SEARCH GROUP NUMBER MODE BY OR MAKE PROGRAMMING GROUP MODE BY DEPRESSING . 2) ENTER GROUP NUMBER. 3) DEPRESS AND THE NEXT PLU NUMBER IS DISPLAYED. 4) DEPRESS AND GROUP NUMBER MODE SUCCESIVELY IS DISPLAYED ON PRICE WINDOW. 5) ENTER GROUP NUMBER 6) BY DEPRESSING AND TURN BY TURN,GROUP MODE NUMBER CAN BE ENTERED SUCCESIVELY WITHOUT PASSING OTHER PLU PROGRAMMING MODE. NOTE: OTHER PLU FILE MODE ALSO CAN BE ENTERED SUCCESIVELY SAME AS ABOVE. F. SUCCESIVE BAR CODE NUMBER ENTERING 1)PRESS < PLU KEY>........ANY PLU NUMBER DISPLAYED 2)ENTER DESIRED PLU NUMBER TO BE ENROLLED..PLU NUMBER ENTERED 3)PRESS ........ ANY PLU FILE MODE DISPLAYED 4)PRESS< MR KEY>..........PLU BAR CODE NUMBER MODE DISPLAYED * BY PRESSING < PRT KEY>, PLU BAR CODE NUMBER MODE CAN BE DISPLAYED 5)ENTER BAR CODE ENUMBER...BAR CODE NUMBER DISPLAYED ON PRICE WINDOW 6)PRESS THE FIXED PRICE KEY WITH SHIFT KEY..PLU NUMBER AND BAR CODE NUMBER ARE INCREASED ONE BY ONE. 7)REPEAT STEP 1 THROUGH 6 TO FURTHER NEW BAR CODE NUMBER. 6. OPERATION PROCEDURE 6-1 NORMAL OPERATION A.OPERATION PROCEDURE BY RECALL PLU NUMBER 1) DEPRESS ..... PLU= SIGN APPEAR ON WEIGHT DISPLAY WINDOW XXX A CERTAIN NUMBER APPEAR ON THE PRICE WINDOW. PLU= XXX WHENEVER DEPRESSING "", PLU NUMBER IS INCREASED ONE BY ONE. 2) ENTER THE PLU NUMBER BY ..... AFTER ENTERING PLU NUMBER,THE SCALE IS READY FOR WEIGHING OR BECOME THE FIXED PRICE MODE. 3) DEPRESS OR .....THIS KEY OPERATION MAKE THE ENTERED PLU NUMBER RECALL. .....IF THE USER INPUT ANY DIGIT NUMBERS, IT MAKE THE UNIT PRICE OR THE FIXED PRICE CHANGE. .....IF THE USER WANT TO RECALL OTHER PLU PROGRAMMING MODE, DEPRESS THE ASSIGNED KEY. 4) DEPRESS ......1 SHEET LABEL IS ISSUED. TOTAL PRICE,WEIGHT,AND OPERATION NUMBER MAKES THE SUM ADDED. REFER THE SUB TOATL LABEL ISSUANCE TO THE SUB TOTAL LABEL OPERATION. B. TEMPORAL CHANGES OF THE STORED PLU DATA WHILE THE USER RECALL THE PLU NUMBER, THE PLU DATA CAN BE CHANGED. IF THE OPERATING MODE IS THE DESIRED MODE TO BE CHANGED, THERE IS NO NEED TO DEPRESS THE ASSIGNED KEY TO RECALL AGAIN. 1) THE UNIT PRICE CHANGE : (1) DEPRESS ...... UNIT PRICE MODE DISPLAY ON WEIGHT WINDOW. (2) KEYING IN THE DESIRED DIGIT KEY TO INPUT .....UNIT PRICE IS DISPLAYED ON UNIT PRICE WINDOW. 2) THE FIXED PRICE CHANGE : (1) DEPRESSING .....THE FIXED PRICE MODE IS DISPLAYED ON THE WEIGHT WINDOW (2) KEYING IN THE DESIRED DIGIT KEY TO INPUT .....THE FIXED PRICE IS DIPLAYED ON PRICE WINDOW. 3) THE FIXED QUANTITY CHANGE : (1) DEPRESS TOGETHER WITH .... THE FIXED MODE IS DISPLAYED ON THE WEIHGT WINDOW. (2) KEYING IN THE DESIRED DIGIT KEY TO INPUT. .....THE FIXED QUANTITY IS DISPLAYED ON THE WEIGHT WINDOW. NOTE: PLEASE REFER THE KEY OPERATION OF THE FIXED QUANTITY MODE, AND UNIT PRICE, THE FIXED QUANTITY MODE AND THE FIXED AMOUNT, THE FIXED PRICE MODE TO THE LABEL ISSUANCE OPERATION 4) TARE WEIGHT CHANGE : (1) DEPRESS THE TOGETHER WITH THE ......TARE MODE IS DISPLAYED ON THE WEIGHT WINDOW. (2) KEYING IN THE DESIRED DIGIT KEY TO INPUT ......THE TARE WEIGHT IS DISPLAYED ON THE WEIGHT WINDOW. (3) DEPRESS THE ...... {-} SIGN IS DISPLAYED ON WEIGHT WINDOW. 5) SHELF LIFE CHANGE : (1) DEPRESS < No.3 KEY> TOGETHER WITH ...... SHELF MODE IS DISPLAYED ON THE WEIGHT WINDOW. (2) KEYING IN THE DESIRED DIGIT TO INPUT ...... THE SHELF LIFE IS DISPLAYED ON THE PRICE WINDOW. (3) DEPRESS THE < UP KEY> . ..... THE SCALE BECOMES NORMAL WEIGHING OPERAION MODE. 6) BAR CODE NO. CHANGE : (1) DEPRESS THE< MR KEY> TOGETHER WITH SHIFT KEY. ....... BARCODE NO. MODE IS DISPLAYED ON TOTAL PRICE WINDOW. (2) KEYING IN THE DESIRED DIGIT KEY TO INPUT ...... THE BAR CODE NUMBER IS DISPLAYED ON THE PRICE WINDOW. (3) DEPRESS THE < UP KEY> ......THE SCALE BECOMES NORMAL WEIGHING OPERATION MODE. 7) GROUP NO. CHANGE : (1) DEPRESS THE < - KEY> TOGETHER WITH < SHIFT KEY> ..... PART(GROUP) MODE IS DISPLAYED ON WEIGH WINDOW. (2) KEYING IN THE DESIRED DIGIT KEY TO INPUT ...... PART NUMBER IS DISPLAYED ON PRICE WINDOW. (3) DEPRESS ......THE SCALE BECOMES NORMAL WEIGHING OPERATION MODE. NOTE:* ALL PROGRAMMING MODE IS INTER-CHANGEABLE FROM ONE MODE TO ANY MODE.RECEIPROCALLY. * ONCE THE TEMPORAL PLU MODE IS CHANGED TO RECALL ANOTHER PLU NUMBER AND BECOMES NORMAL WEIGHING MODE AGAIN, THE TEMPORAL DATAS ENTERED IS EXTINGUISHED AND THE STORED DATA BY PROGRAMMING IS RECOVERED. 6-2 KEY SWITCH OPERATION ( NON-PLU NUMBER OPERAION) A. WEIGHT,UNIT PRICE, PRICE LABEL ISSUANCE 1) DEPRESS < UP KEY> ...... UP MODE IS DISPLAYED ON WINDOW. 2) KEYING IN DIGIT KEY ......UNIT PRICE IS DISPLAYED ON THE UNIT PRICE WINDOW. 3) LOAD WEIHGTS ON PLATTER .......WEIGHT ,PRICE IS DISPLAYED ON THE WEIGHT AND PRICE WINDOW. 4) DEPRESS ........1 SHEET LABEL ISSUED *NOTE: SEE THE SUB TOTAL LABEL ISSUANCE PROCEDURE. B. THE FIXED PRICE LABEL ISSUANCE 1) DEPRESS THE .....FIXED PRICE MODE IS DISPLAYED ON PRICE WINDOW. 2) KEYING IN THE DESIRED PRICE TO INPUT. ........FIXED PRICE DISPLAYED ON WINDOW. 3) DEPRESS< PRT KEY> .......1 SHEET LABEL ISSUED. C. FIXED PRICE ,FIXED AMOUNT LABEL ISSUANCE. 1) DEPRESS THE< FIXED KEY> .......FIXED MODE IS DISPLAY ON WINDOW PRICE. 2) KEYING IN DIGIT KEY ......FIXED PRICE IS DISPLAYED ON PRICE WINDOW. 3) DEPRESS THE< X KEY> TOGETHER WITH ......FIXED Q'TY MODE IS DISPLAYED ON WEIGHT WINDOW. 4) KEYING IN FIXED WEIGHTS ......FIXED WEIGHTS IS DISPLAYED ON THE WEIGHT WINDOW. 5) DEPRESS .........1 SHEET LABEL ISSUED *NOTE: SEE THE SUB TOTAL LABEL ISSUANCE PROCEDURE *CAUTION: KEEP THE ENTERING ORDER. IF THE FIXED PRICE KEY ENTERED LATER THAN FIXED QUANTITY, THE WEIGHT FIRST ENTERED IS TO BE EXTIGUSHED. D. UNIT PRICE , FIXED QUANTITY, PRICE LABEL ISSUANCE 1) DEPRESS" .....UP MODE IS DISPLAYED ON THE WEIGHT WINDOW. 2) KEYING IN DIGIT KEY .......UNIT PRICE IS DISPLAYED ON PRICE WINDOW. 3) DEPRESS TOGETHER WITH .......FIXED QUANTITY MODE DISPLAYED ON WEIGHT WINDOW. 4) KEYING IN THE DESIRED FIXED QUANTITY TO INPUT .......FIXED QUANTITY IS DISPLAYED ON WEIGHT WINDOW. 5) DEPRESS ........1 SHEET LABEL ISSUANCE * NOTE: ENTERING ORDER CAN BE EXCHANGED. SEE THE SUB TOTAL LABELL ISSUANCE PROCEDURE. E. FIXED PRICE BY COUNT,PRICE LABEL ISSUANCE 1) DEPRESS ........FIXED PRICE MODE IS DISPLAYED ON THE WEIGHT WINDOW. 2) KEYING IN THE DESIRED DIGIT KEY TO INPUT FIXED PRICE ........FIXED PRICE IS DISPLAYED ON PRICE WINDOW. 3) DEPRESS ........FIXED PRICE IS DISPLAYED ON WEIGHT WINDOW AND BECOME COUNT NUMBER MODE. 4) KEYING IN THE DESIRED COUNT NUMBER TO INPUT ........COUNT NUMBER QUANTITY IS DISPLAYED ON UNIT PRICE WINDOW. AND TOTAL PRICE IS ALSO DISPLAYED ON PRICE WINDOW. 5) DEPRESS< PRT KEY> ........1 SHEET LABEL ISSUANCE NOTE: SEE SUB TOTAL LABEL ISSUANCE PROCEDURE 6-3 TOTAL LABEL(SUB TOTAL) ISSUANCE FOR EVERY CUSTOMER. THE USER CAN MAKE THE SUM OF TOTAL TRANSACTION AND PAYMENT DEPOSIT AND CLEAR THE BALANCE FOR A SPECIFIC CUSTOMER , AND CALCULATE THE CHANGES. A. CLEARING LABEL ISSUANCE AT EVERY STEP. WHENEVER THE USER CLEARE ONE TRANSACTION, LABEL IS ISSUED EVERY TIME. 1) DEPRESS ..... TOTAL WEIGHT IS DISPLAYED ON WEIGHT WINDOW. TOTAL TRANSACTION NUMBER IS DISPLAYED ON THE UNIT PRICE WINDOW. TOTAL AMOUNT IS DISPLAYED ON THE PRICE WINDOW. 2) KEYING IN THE DEPOSIT AMOUNT PAID BY A CUSTOMER ......DEPOSIT AMOUNT IS DISPLAYED ON THE PRICE WINDOW. 3) DEPRESS < PRT KEY> ......THE BALANCE OF CHANGE IS DISPLAYED ON THE PRICE WINDOW. AFTER ISSUING ONE LABEL, THE SCALE IS READY FOR NEXT NORMAL WEIHGING OPERATION. * NOTE : MEMORIZED SUB TOTAL ACCUMULATOR IS ALL CLEARED. : IF MINUS AMOUNT(-XXX) IS DISPLAYED ON THE PRICE WINDOW, IT REFLECT THE DEPOSIT MONEY IS SMALLER THAN TOTAL TRANSACTION ACCUMULATING AMOUNT. IN THIS CASE, PLEASE REPEAT THE CLEAR PROCEDURE AGAIN FROM THE BEGINNING FOLLOWING AS ABOVE PROCEDURE. B.CLEARING ALL THE TRANSACTION ONLY BY ONE SUB TOTAL LABEL ISSUANCE. DURING THE PLU OPERATION OR TEMPORAL PLU CHANGE OPERATION OR KEY SWITCH OPERATION, PLEASE PROCEED THE BELOW OPERATION TO CLEAR THE TRANSACTION FOR A SPECIFIC CUSTOMER. CAUTION: DO NOT DEPRESS THE WHILE THIS OPERATION IS UNDERGONE. FOLLOW THE BELOW PROCEDURE, NOT PRESSING 1) PRESS< M+ KEY> ...... WHOLE DISPLAY BLINK MOMENTALLY AND < M+ PROCESSING SIGNAL> IS LIT AND DATA IS ADDED TO THE TOTAL. 2) PRESS ......WHOLE DISPLAY BLINK MOMENTALLY AND IS LIT AND THE DATA IS DEDUCTED FROM THE TOTAL. BUT THE FREQUENCY IS ADDED TO THE TRANSACTION NUMBER. 3) PRESS SUB TOTAL . ......WEIGHT, FREQUENCY ,TATAL AMOUNT DISPLAYED 4) PRESS ......THE FINAL DATA DISPLAYED RESULTING FROM ADDING OR DEDUCTING THE SUM. NOTE: BY PRESSING ,THE PREVIOUS DATA OF SUM IS DISPLAYED TURN BY TURN. WHILE CLEARING THE TOTAL, THE DATA CAN BE CALCULATED BY USING THE NEXT PROCEDURE IS SAME AS "A" PROCEDURE. 5) PRESS SUB TOTAL KEY. 6) KEYING IN THE DEPOSIT AMOUNT. 7) DEPRESS NOTE: THE DIFFERNECE BETWEEN A AND B IS THAT PROCEDURE A ISSUE LABEL AT EVERY STEP OF CLEARANCE AND B ISSUE ONLY ONE LABEL BY CLEARING ALL STEPS ON SCALE. 6-4 TEMPORAL STOP OF LABEL ISSUANCE THIS IS THE PROCEDURE TO STOP LABEL ISSUANCE TEMPORALLY. 1) PRESS TOGETHER WITH .....ALL DISPLAY BLINKED AND THE LABEL ISSUANCE STOP INDICATOR IS LIT AND LABEL ISSUANCE STOP. 2) REPEAT THE SAME OPERATION TO RECOVER THE LABEL ISSUANCE. 6-5 TARE WEIGHT SUBTRACTION TWO WAY OF TARE SUBTRACTION IS AVAILABLE: ONE IS MANUAL INPUT BY DIGIT KEY OR TARE KEY , ANOTHER IS PLU PROGRAMMING INPUT METHOD. A.TARE WEIGHT SUBTRACTION BY TARE KEY 1) PUT CONTAINER ON THE SCALE PLATTER .....TARE WEIGHT DISPLAYED ON WEIGHT WINDOW. 2)PRESS ....."0" DISPLAY ON WINDOW. 3) PUT AWAY THE CONTAINER FROM PLATTER. ......TARE WEIGHT IS DISPLAYED WITH [-] SIGN ON WEIGHT WINDOW. 4) WEIGHTS WITH A CONTAINER DISPLAY NET WEIGHT. B. TARE WEIGHT SUBTRACTION BY DIGIT KEY 1) DEPRESS TOGETHER WITH ......TARE WEIGHT INPUT MODE DISPLAY ON WINDOW. 2) KEYING IN TARE WEIGHT BY ......TARE WEIGHT IS DISPLAYED ON WEIGHT WINDOW. 3) DEPRESS ......TARE WEIGHT DISPLAYED WITH [-] SIGN ON WINDOW. THIS IS USED TO SUBTRACT THE TARE WEIGHT WHEN OPERATOR KNOW THE CONTAINER WEIGHT IN ADVANCE. C. TO RELEASE THE TARE WEIGHT : 1) DEPRESS < TARE KEY> OR < UP KEY> .. ...[-] SIGN IS EXTINGUISHED AND TARE OPERATION IS RELEASED. 6-6 VARIOUS CLEAR FUNCTION KEY * THIS KEY IS USED TO CLEAR SOME CONTENTS FROM THE PLU NUMBER NOT TO PRINT ON LABEL. * ITEM NAME, BAR CODE, WEIGHT, UNIT PRICE, TOTAL PRICE CAN BE DELETED PARTIALLY OR WHOLLY BY USING THIS KEY. A. TO DELETE ITEM NAME TEMPORALLY ON LABEL PRINTING 1) DEPRESS TOGETHER WITH .. ...Prn Off BLINKED ON PRICE WINDOW AND SIGN INDICATOR IS LIT. TO RECOVER, PRESS SAME KEY AS BEFORE B. TO DELETE BARCODE NO. TEMPORALLY ON LABEL PRINTING 1) DEPRESS TOGETHER WITH .....BAR off BLINKED ON PRICE WINDOW AND SIGN INDICATOR IS LIT. 2) TO RECOVER, PRESS SAME KEY AS BEFORE C. TO DELETE WEIGHT TEMPORALLY ON LABEL PRINTING 1) DEPRESS TOGETHER WITH ..... WGt OFF BLINKED ON PRICE WINDOW AND WEIGHT CLEAR SIGN IS LIT. 2) SAME REPEATED OPERATION RECOVER TO PRINT WEIGHT ON LABEL D. TO DELETE UNIT PRICE TEMPORALLY ON LABEL PRINTING 1) DEPRESS TOGETHER WITH .....uP OFF BLINKED ON PRICE WINDOW AND UNIT PRICE CLEAR SIGN IS LIT. INDICATOR 2) SAME REPEATED OPERATION RECOVER TO PRINT UNIT PRICE ON LABEL E. TO DELETE TOTAL PRICE TEMPORALLY ON LABEL PRINTING 1) DEPRESS TOGETHER WITH ..tP OFF BLINKED ON PRICE WINDOW AND TOTAL PRICE CLEAR SIGN IS LIT. 2) SAME REPEATED OPERAION RECOVER TO PRINT TOTAL PRICE ON LABEL. NOTICE: BE CAREFUL AT THE SIGN LIGHT OF CLEAR OPERATION, BECAUSE THE WEIGH,UNIT PRICE AND TOTAL PRICE IS DISPLAYED ON THE WINDOW WHILE LABEL PRINTING CLEAR PROCEDURE IS UNDERGOING LIKE A NORMAL OPERATION. 7. RETRIEVING MANAGEMENT DATA 7-1 DAILY TOTAL REPORT LABEL ISSUANCE A. TO ISSUE LABEL ALL ACCUMULATORS -SORTED BY PLU 1) PRESS WITH SHIFT KEY ...TOTAL AMOUNT DISPLAYED ON THE PRICE WINDOW 2) PRESS ...................TOTAL WEIGHT,TOTAL TRANSACTIONS, TOATL AMOUNT LABEL WILL ISSUE 3) ALL DAILY ACCUMULATORS ARE NOW RESET TO ZERO B. TO CONFIRM SUM ON WINDOW 1) PRESS WITH SHIFT KEY... TOTAL AMOUNT DISPLAYED ON THE PRICE WINDOW 2) PRESS ................THE TOTAL PRICE LABEL ONLY WILL ISSUE C. TO CLEAR ALL ACCUMULATOR 1) PRESS ...............TOTAL AMOUNT DISPLAYED 2) PRESS ...............ALL DATA BECOMES "0" 3) PRESS ...............SCALE IS READY FOR OPERATION * OTHER KEY CAN WORK SAME AS 8. LABEL SIZE, PRINTING CONTENT, PRINTING LOCATION THE WIDTH, LENGTH, PRINTING DATA, AND LOCATION SHOULD BE PROGRAMMED AT THE PROG . FUNCTION MODE. 9. TROUBLE: BEFORE YOU CALL SERVICE OUR PRIMARY CONCERN IS TO GIVE YOU FULL SATISFACTION AND BETER SERVICE.HOWEVER IF ANY PROBLEM ARISES IN CONNECTION WITH THE OPERATION OF THIS SCALE, PLEASE CHECK FOLLOWING POINTS ONCE MORE BEFORE CALLING SERVICE. (1) IS THE POWER PLUG INSERTED IN THE OUTLET? (2) IS'NT IT THE POWER-FAILURE CASE. (3) HAS THE OPERATION BEEN CARRIED OUT IN CORRECT ORDER. IF YOU FIND ANY TROUBLE OR INCONVENIENCE,DO NOT TRY TO FIX BY YOURSELF, PULL THE POWER PLUG OUT OF THE WALL OUTLET, AND IMMEDIATELY CONTACT WITH YOUR REPRESENTATIVE. 10. ERROR MESSAGE 11. COMPUTER INTERFACE/SCALE CONNECTION RS 232 AND RS 485 IS INSTALLED . ------------------------------------------------------------------------------ 3) FUNCTION PROGRAMMING SUMMARY THIS IS USED TO PRESET THE SCALE FUNCTION SUCH AS UNIT PRICE DIGIT SET UP. ETC. (REFER TO FOLLOWING PRESET CONTENTS) FUNCTION DATA IS composed of 3 DIGIT. AT THIS MOMENT THE 138 FUNCTION DATA IS RESISTERED. THE FUNCTION PROGRAMMING PROCEDURE. 1) PLACE KEY LOCK AT THE PROG. POSITION. 2) DEPRESS ON/ZERO KEY 3) F 0000 IS DISPLAYED. THIS IS READY FOR PRESETTING THE SCALE FUNCTION. FOLLOWINGS ARE EVERY FUNCTION PROGRAMMING LIST. IF ANY FIGURE NOT PROVIDED IN THE DATA,ERROR SIGN IS DISPLAYED. 1) FUNC 000; LABEL FORM PRESETTING DATA. CHOICE RANGE IS 0 TO 99 DATA 0 IS USER LABEL ONLY. THIS FUNCTION IS CONNECTED WITH FUNC 001. DATA RANGING FROM 1 TO 99 IS STANDARD FORM. CAUTION: WHEN THE USER CHOICE DATA 3 LABEL AND MODIFY SOME CONTENTS, IF THE USER CHOICE DATA 3 AGAIN , THE MODIFIED LABEL IS REMAINED INSTEAD OF PREVIOUS ONE. BUT AFTER MODIFYING THE LABEL ,IF THE USER CHOICE ANOTHER DATA NUMBER SUCH AS DATA 4, AND WHEN HE DEPRESS AGAIN NUMBER 3 DATA, THE LABEL FORM BECOME THE PREVIOUS ONE WHICH WERE NOT MODIFIED. 2) FUNC 001 IN CASE OF SELECT 0 AT FUNCTION 000, THE USER ONLY LABEL FORM CAN BE PRESET RANGING FROM 1 TO 99. CAUTION: WHEN PRESETTING THE DATA, " 11" SHOULD BE ENTERED IN ADVANCE. EX. 11 23 3) FUNC 002; THE LABEL WIDTH PRESETTING DATA. PRESETTING RANGE IS 40 OR 60 COLUMN. ACCORDING TO THE LABEL WIDTH, INPUT SMALLER COLUMN NUMBER SUCH AS 56 IN CASE OF 60 MM WIDTH LABEL. 4) FUNC 003; LABEL LENGTH PRESETTING DATA. PRESETTING RANGE IS 20 TO 90 LINE. ACCORDING TO THE LABEL LENGTH, INPUT LONGER DATA THAN LABEL LENGTH SUCH AS 67 MM IN CASE OF 63 MM LENGTH LABEL 5) FUN. 004 LABEL FORM LINE 1 SPECIFICATION PRESETTING DATA. THE FUNCTION PROGRAMMING FROM FUN.004 TO FUN.027 IS A BASIC LABEL FORM PRESETTING RANGE. MODIFICATION OF WHOLE FORM IS AVAILABLE. FUNCTION PRESETTING EXAMPLE THE TOTAL 6 DIGIT DATA 00 00 00 IS DIVIDED INTO EACH TWO DIGIT GROUP. FIRST TWO DIGIT IS THE LETTER SIZE, SECOND TWO DIGIT IS THE LOCATION OF LINE AND THE THIRD TWO DIGIT IS THE STARTING POINT OF COLUMN. IN CASE THE USER WANT TO USE 3 LETTER SIZE, 16 LINE LOCATION, STARTING FROM 25 CULUMN LABEL, ENTER 031625 DATA FOR THE DESIRED LABEL FORM. THE DATA INPUT METHOD IS ALL SAME FROM FUN.004 TO FUN.027. 6) FUN.005 LABEL FORM PRESETTING DATA LINE 2 SPECIFICATION S DATA INPUT IS SAME AS FUN.004 7) FUN. 006 LABEL FORM PRESETTING DATA LINE 3 SPECIFICATIONS DATA INPUT IS SAME AS FUN.005 8) FUN. 007 LABEL FORM PRESETTING DATA LINE 4 SPECIFICATIONS DATA INPUT IS SAME AS FUN.006 9) FUN. 008 LABEL FORM PRESETTING DATA LINE 5 SPECIFICATIONS DATA INPUT IS SAME AS FUN.007 10) FUN 009 LABEL FORM PRESETTING DATA LINE 6 SPECIFICATIONS DATA INPUT IS SAME AS FUN.008 11) FUN. 010 LABEL FORM PRESETTING DATA ADVERTISEMENT LINE 1 SPECIFICATIONS DATA INPUT IS SAME AS FUN. 009 12) FUN. 011 LABEL FORM PRESETTING DATA BAR CODE LINE SPECIFICATIONS DATA INPUT IS SAME WAY AS FUN 010 13) FUN. 012 LABEL FORM PRESETTING DATA TOTAL PRICE LINE SPECIFICATIONS DATA INPUT IS SAME WAY AS FUN.011 13) FUN. 012 LABEL FORM PRESETTING DATA WEIGHT LINE SPECIFICATIONS DATA INPUT IS SAME WAY AS FUN.011 14) FUN. 013 LABEL FORM PRESETTING DATA UNIT PRICE LINE SPECIFICATIONS DATA INPUT IS SAME WAY AS FUN.012 15) FUN 014 LABEL FORM PRESETTING DATA TOTAL PRICE LINE SPECIFICATIONS DATA INPUT IS SAME WAY AS FUN.013 16) FUN 015 LABEL FORM PRESETTING DATA PRODUCTION DATE LINE SPECIFICATIONS DATA INPUT IS SAME WAY AS FUN.014 17) FUN 016 LABEL FORM PRESETTING DATA EXPIRY DATE LINE SPECIFICATIONS DATA INPUT IS SAME WAY AS FUN.015 18) FUN 017 LABEL FORM PRESETTING DATA TIME LINE SPECIFICATIONS DATA INPUT IS SAME WAY AS FUN.016 19) FUN 018 LABEL FORM PRESETTING DATA GROUP NO. PRINTING LINE SPECIFICATIONS DATA INPUT IS SAME WAY AS FUN.017 20) FUN 019 LABEL FORM PRESETTING DATA COMPANY NAME PRINTING LINE SPECIFICATIONS DATA INPUT IS SAME WAY AS FUN.018 21) FUN 020 LABEL FORM PRESETTING DATA ADRESS PRINTING LINE SPECIFICATIONS DATA INPUT IS SAME WAY AS FUN.019 22) FUN 021 LABEL FORM PRESETTING DATA TELEPHONE PRINTING LINE SPECIFICATIONS DATA INPUT IS SAME WAY AS FUN.020 23) FUN 022 LABEL FORM PRESETTING DATA COMPANY RESISTER NO. PRINTING LINE SPECIFICATIONS DATA INPUT IS SAME WAY AS FUN.020 24) FUN 023 LABEL FORM PRESETTING DATA DESCRIPTION PRINTING LINE 1 SPECIFICATIONS DATA INPUT IS SAME WAY AS FUN.022 25) FUN 024 LABEL FORM PRESETTING DATA DESCRIPTION PRINTING LINE 2 SPECIFICATIONS DATA INPUT IS SAME WAY AS FUN.023 26) FUN 025 LABEL FORM PRESETTING DATA DESCRIPTION PRINTING LINE 3 SPECIFICATIONS DATA INPUT IS SAME WAY AS FUN.024 27) FUN 026 LABEL FORM PRESETTING DATA DESCRIPTION PRINTING LINE 4 SPECIFICATIONS DATA INPUT IS SAME WAY AS FUN.025 28) FUN 027 LABEL FORM PRESETTING DATA DESCRIPTION PRINTING LINE 5 SPECIFICATIONS DATA INPUT IS SAME WAY AS FUN.026 29) FUN 028 LABEL FORM PRESETTING DATA CODE NO. PRINTING LINE SPECIFICATIONS DATA INPUT IS SAME WAY AS FUN.027 30) FUNC 029; ADVERTISEMENT LIBRARY NUMBER INPUT PROGRAMMING DATA. EX. IF THE USER INPUT 1111, THE LIBRARY NUMBER 1111 IS PRINTED ON THE LABEL IN THE OCASION OF THE FUNC 49 MODE DATA PRESETED AS 1. 31) FUNC 30; THE SHOP NAME LIBRARY NUMBER INPUT PRESETTING DATA. EX. IF THE USER INPUT 1112, THE LIBRARY 1112 IS PRINTED ON THE LABEL. 32) FUNC 31; THE ADRESS LIBRARY NUMBER INPUT PRESETTING DATA EX. IF THE USER INPUT 1113 , THE LIBRARY 1113 IS PRINTED ON THE LABEL AS A ADRESS. 33) FUNC 32; THE TELEPHON LIBRARY NUMBER INPUT PRESETTING PROGRAM DATA. EX. IF THE USER INPUT 1114, THE LIBRARY NUMBER 1114 IS PRINTED ON THE LABEL AS A TELEPHON NUMBER. 34) FUNC 33; THE COMPANY RESISTER LIBRARY NMUMBER INPUT PRESETTING PROGRAM DATA. EX. IF THE USER INPUT 1115, THE LIBRARY NUMBER IS PRINTED ON LABEL AS A LICENSE RESISTER NUMBER OF A SHOP. 35) FUNC 34; THE DESCRIPTION LINE 1 LIBRARY NMUMBER INPUT PRESETTING PROGRAM DATA. EX. IF THE USER INPUT 1115, THE LIBRARY NUMBER IS PRINTED ON LABEL AS A DESCRIPTION LINE 1. 36) FUNC 35; THE DESCRIPTION LINE 2 LIBRARY NMUMBER INPUT PRESETTING PROGRAM DATA. EX. IF THE USER INPUT 1116, THE LIBRARY NUMBER IS PRINTED ON LABEL AS A DESCRIPTION LINE 2. 37) FUNC 36; THE DESCRIPTION LINE 3 LIBRARY NMUMBER INPUT PRESETTING PROGRAM DATA. EX. IF THE USER INPUT 1117, THE LIBRARY NUMBER IS PRINTED ON LABEL AS A DESCRIPTION LINE 3. 38) FUNC 37; THE DESCRIPTION LINE 4 LIBRARY NMUMBER INPUT PRESETTING PROGRAM DATA. EX. IF THE USER INPUT 1118, THE LIBRARY NUMBER IS PRINTED ON LABEL AS A DESCRIPTION LINE 4. 39) FUNC 38; THE DESCRIPTION LINE 5 LIBRARY NMUMBER INPUT PRESETTING PROGRAM DATA. EX. IF THE USER INPUT 1119, THE LIBRARY NUMBER IS PRINTED ON LABEL AS A DESCRIPTION LINE 5. 40) FUNC 39; BAR CODE LENGTH PRESETTING DATA. PRESETTING RANGE 1- 00 41) FUNC 40; BAR CODE SPECIFICATION PRESETTING DATA. REFER THE DATA TO THE BELOW TABLE FOR THE CHOICE AND EXPLANATION OF THE BAR CODE SPECIFICATIONS. --------------------------------------------------------------------- DATA DIGIT VERTICAL/ BARCODE CHECK PRICE PRICE - NUMBER HORIZONTAL DIGIT NUMBER DIGIT NUMBER DIGIT NUMBER ------------------------------------------------------------------------ 00 13 V 4 1 5 01 13 V 5 1 4 02 13 V 5 X 5 03 13 V 6 X 4 ----------------------------------------------------------------------- 04 8 V 0 1 5 05 8 V 1 1 4 06 8 V 1 X 5 07 8 V 2 X 4 ----------------------------------------------------------------------- 10 13 H 4 1 5 11 13 H 5 1 4 12 13 H 5 X 5 13 13 H 6 X 4 ---------------------------------------------------------------------- 14 8 H 0 1 5 15 8 H 1 1 4 16 8 H 1 X 5 17 8 H 2 X 4 ---------------------------------------------------------------------- 42) FUNC 041; BAR CODE PRINTING SIZE PRESETTING DATA . DATA RANGE: 0,1,2 DATA 0 MAKES THE BARCODE PRINTING STANDARD DATA 1 MAKES THE BARCODE PRINTING SMALL ONE COLUMN TO THE LEFT DATA 2 MAKES THE BAR CODE PRINTING SMALL TWO COLUMN TO THE LEFT 43) FUN 042 THE LENGTH OF THE LABEL PRESETTING DATA IN CASE OF 63MM LABEL , THE DATA BECOMES 533MM. 44) FUN 043 THE STOP LOCATION OF THE LABEL ISSUANCE PRESETTING DATA INPUT THE DATA CALCULATED ACCORDING TO THE LENGTH OF THE LABEL. EX. IN CASE OF 63MM LENGTH LABEL , THE DATA IS 120. INPUT 120 45) FUN. 044; THE COUNTRY CODE NUMBER OF THE BAR CODE PRESETTING DATA. IT DEPENDS ON THE COUNTRY CODE NUMBER WHICH IS APPLIED TO ITS COUNTRY. 46) FUN.045; AUTO SPACE ADJUSTING FUNCTION INPUT DATA OF THE ITEM NAME PRINTING ON THE LABEL. DATA RANGE : 0,1 DATA 0 IS TO PRINT ITEM NAME WITHOUT CHANGES. DATA 1 IS TO PRINT ITEM NAME AUTOMATICALLY ADJUSTING THE SPACE OF THE LABEL. 47) FUNC 046 ITEM NAME LETTER SIZE ADJUSTING PROGRAMMING DATA. IN CASE OF DATA 1 PRESETTING: IF THE ITEM NAME IS LARGER THAN THE EXISTING LABEL WIDTH, THE ITEM NAME BECOME SMALL TO MEET THE LABEL SIZE AUTOMATICALY. DATA 0 MAKE THE ITEM NAME NOT TO BE SMALL. DATA 1 MAKE THE ITEM NAME SMALL AUTOMATICALLY. 48) FUNC 047; MANUFACTURING DATE AND SHELF LIFE YEAR MONTH DATE ORDER PROGRAMMING DATA DATA RANGE: 0,1,2,3 DATA 0 MAKES YY . MM. DD. DATA 1 MAKES DD. MM. YY. DATA 2 MAKES YY . MM. DD. DATA 3 MAKES MM. DD. YY. 49) FUNC 048; TIME DISPLAY PROGRAMM DATA DATA RANGE: 0,1 DATA 0 DISPLAY 0 TO 24 ARMY TIME SYSTEM. DATA 1 DISPLAY 0 TO 12, AM, PM TIME SYSTEM. 50) FUN 049 ADVERTISEMENT PRINTING PRESETTING DATA DATA 1, 0 DATA 1: PRINT THE ADVERTISEMENT DATA 0: EXCLUDE THE ADVERTISEMENT PRINTING 51) FUN.050 TO FUN.065 IS SUPERVISER PROGRAMM DATA. NEEDS PASSWORD P 1 52) FUN.066; DECIMAL POINT PRESETTING PROGRAMMING DATA. PRESETTING RANGE IS 00 TO 66. THE FIRST DIGIT DECIDE WEIGHT DISPLAY DECIMAL POINT PRESETTING DATA. THE SECOND DIGIT DECIDE UNIT PRICE ,PRICE DECIMAL POINT PRESETING DATA. 53) FUNC 067; NEEDS PASSWORD P 2 . SCALE INITIALLIZING PROGRAMMING DATA PRESETTING DATA RANGE 0 TO 9 EX. DATA 8 ERASE ALL PLU DATA DATA 9 INITIALIZE FUNCTION PROGRAMMING STEP. LIBRARY IS ALL ERASED. DATA 0 TO 7 IS NOT USED AT PRESENT 54) FUN.068; DATA FOR PRESETTING OF TOTAL PRICE DIGIT. PRESETTING DADTA RANGE 0 TO 8 DATA 7 MAKE THE GRAND TOTAL, SUB TOTAL, PLU TOTAL TO BE LIMITTED AT DIGIT 7. 55) FUN.069; GRAND TOTAL , SUBTOTAL MANAGING PROGRAMMING DATA. DATA RANGE: 0,1,2,3 DATA 0 MAKE GRAND TOTAL , SUBTOTAL TO BE ADDED. DATA 1 MAKE GRAND TOTAL ONLY TO BE ADDED. DATA 2 MAKE SUB TOTAL ONLY TO BE ADDED. DATA 3 MAKES GRAND TOTAL, SUB TOTAL BOTH NOT TO BE ADDED. 56) FUN, 070; NEEDS PASSWORD P 2. CALIBRATION PROGRAMMKING DATA. PROCEDURE 1. DEPRESS< ZERO KEY> TO MAKE SCALE ZERO 2. INPUT THE WEIGHT OF THE STANDARD WEIGHT VALUE BY DIGIT KEY. THE WEIGHT VALUE IS DISPLAYED ON PRICE WINDOW. IF THE CALIBRATION WEIGHT DATA IS 1KG, INPUT 1000 BY DIGIT KEY, 1000 IS DISPLAYED ON THE PRICE WINDOW. 3. PLACE THE STANDARD WEIGHT 1 KG ON THE PLATTER . THE A/D VALUE PER 1 KG IS DISPLAYED ON THE WEIGHT WINDOW. 4. WAIT FOR A SECDOND TO STABILIZE THE SCALE AND DEPRESS ENTER KEY TO STORE THE WEIGHT FOR CALIBRATION. 5. AFTER JUST FEW SECOND, THE CALIBRATION DATA 1000 IS DISPLAYED ON THE PRICE WINDOW. 6. INPUT THE SECOND STANDARD WEIGHT VALUE BY DIGIT KEY. THE WEIGHT VALUE IS DISPLAYED ON PRICE WINDOW. IF THE CALIBRATION WEIGHT DATA IS 2KG, INPUT 2000 BY DIGIT KEY. 2000 IS DISPLAYED ON THE PRICE WINDOW. 7. PLACE THE STANDARD WEIGHT ON THE PLATTER. THE A/D VALUE PER 2 KG IS DISPLAYED ON THE WEIGHT WINDOW. 8. WAIT FOR A SECDOND TO STABILIZE THE SCALE AND DEPRESS ENTER KEY TO STORE THE WEIGHT FOR CALIBRATION. 9. AFTER JUST FEW SECOND, THE CALIBRATION DATA 2000 IS DISPLAYED ON THE PRICE WINDOW. 10. REPEAT STEP 6 THROUGH 9 TO FURTHER CALIBRATION, COMPLYING WITH THE CALIBRATION DATA, IF THE FUNCTION IS PRESET BY MULTI RANGE. 57) FUN. 071 TO FUN.080 THIS FUN. DATAS ARE CONCERNED WITH THE CALIBRATION OF THE SCALE . AND RELATED WITH FUN.O7O FOLLOWINGS. NOTE: FUNC 77. 78, 79 NEED PASSWORD P2. 58) FUN. 081; SCALE MAXIMUM LOADING CAPACITY ALLOWANCE PRESETTING PROGRAMMING. EX. IF THE DATA 20 INPUT , THE MAXIMUM SCALE LOADING CAPACITY SHALL BE CALCULATED AS SCALE CAPACITY X 1.2 = MAXIMUM LOADING CAPACITY. IF THE SCALE CAPACITY IS 6000 KG, THE MAXIMUM SCALE LOADING CAPACITY SHALL BE 6000 X 1.2 = 7200 59) FUN. 082; ZERO RANGE PRESETTING PROGRAMMING IF THE DATA 20 INPUT, SCALE ZERO RANGE SHALL BE CALCURATED AS SCALE CAPACITY X 0.2 = SCALE MAXIMUM ZERO RANGE. IF THE SCALE CAPACITY IS 6000 AND DATA 20 INPUT 6000 X 0.2= 1200 IN THIS CASE THE SCALE ZERO RANGE IS 1200. IT MEANS ZERO KEY IS EFFECTED WITHIN THE RANGE 1200. 60) FUN. 083; TARE RANGE PRESETTING PROGRAMM. IF DATA 50 INPUT, THE MAXIMUM TARE RANGE IS CALCULATED AS SCALE CAPACITY X 0.5= TARE RANGE. IF THE SCALE CAPACITY IS 6000 AND DATA 0.5 6000X 0.5= 3000. THE MAXIMUM TARE RANGE IS 3000 AND THE TARE KEY IS EFFECTIVE UPTO THE 3000. 61) FUN. 084; PRICE PRESETTING PROGRAMM DATA 0 IS REGULAR PRICE DATA 1 IS 1/2,1/4 PRICE MODE. WHILE NORMAL OPERATING, DEPRESSING OF 1/2 OR 1/4 KEY THE PRICE BECOME TWO TIMES OR FOUR TIMES. THIS PRESETTING PROGRAM IS RELATED WITH THE WEIGHT UNIT OF EACH COUNTRY. 62) FUN. 085; METROLOGIC UNIT PRESETTING PRGRAMMING DATA DATA 0 CONVERTS KG TO KG DATA 5 CONVERTS KG TO LB DATA 6 CONVERTS LB TO KG DATA 7 CONVERTS LB TO LB 63) FUN. 086; UNIT PRICE CLEAR PROGRAMING DATA. DPRESSING UNIT PRICE KEY WITH SHIFT KEY MAKE THE UNIT PRICE CLEAR OR NOT CLEAR BY DEPRESSING C.UP KEY. DATA 0 MAKE C.UP KEY DO NOT WORK. DATA 1 MAKE C.UP KEY WORK. IN CASE OF ENTERING DATA 1.; AT NORMAL OPERATION, IF TTHE C.UP KEY IS DEPRESSED, [C.UP ON] SIGN IS APPEARED FOR 0.5 SECOND AND UNIT PRICE IS CLEAR AND AFTER ONCE ESTABLISHING THIS FUNCTION, THE UNIT PRICE IS CLEARED EVERY TIME THE WEIGHT IS REMOVED AND DISPLAY 0 ON WEIGHT WINDOW, THE UNIT PRICE IS AUTOMATICCALLY CLEARED. IF C.UP KEY IS DEPRESSED ONE MORE TIME, THE FUNCTION IS RELEASED AFTER SHOWING [C.UP OFF] FOR 0.5 SECOND. 64) FUN. 087; WHEN DEPRESSING 2ND PRICE KEY (2 TP KEY), VALUE ADDED TAX PRESETTING PROGRAMMING DATA. EX. IF 20 IS ENTERED, THE PRICE IS CALCULATED AUTOMATICCALLY BY 20 % INCREASED. PRICE X 1.2= PRICE 20% UP 65) FUN. 088; THIS DATA IS CONNECTED WITH FUNC 87 AND REFER THE CHART TO CALCULATION. DATA DESCRIPTION DIGIT -------------------------------------------------------- OO ALL IMPOSSIBDLE 20 TAX + ROUNDING UP 1 DIGIT 21 TAX + ROUNDING UP 10 DIGIT 22 TAX + ROUNDING UP 100 DIGIT 23 TAX + ROUNDING UP 1000 DIGIT -------------------------------------------------------- 24 TAX + CUT 1 DIGIT 25 TAX + CUT 10 DIGIT 26 TAX + CUT 100 DIGIT 27 TAX + CUT 1000 DIGIT ------------------------------------------------------- - 30 TAX NO+ ROUNDING UP 1 DIGIT 31 TAX NO+ ROUNDING UP 10 DIGIT 32 TAX NO+ ROUNDING UP 100 DIGIT 33 TAX NO+ ROUNDING UP 1000 DIGIT --------------------------------------------------------- 34 TAX NO+ CUT 1 DIGIT 35 TAX NO+ CUT 10 DIGIT 36 TAX NO+ CUT 100 DIGIT 37 TAX NO+ CUT 1000 DIGIT ---------------------------------------------------------- 66) FUN. 089; GRAVITY VALUE PRESETTING PROGRAMMING. ENTER GRAVITY VALUE ACCORDINJG TO THE CHANGES BY ALTITUDE. STANDARD VALUE IS 10,000,000 67) FUN. 090; PLU DATA SAVE PRESETTING PROGRAMMING AT NORMAL OPERATION. DATA 0 MAKE PLU NOT TO SAVE IN NORMAL OPERATION. DATA 1 MAKES PLU SAVE IN NORMAL OPERATION. 68) FUN. 091; IN CASE MANUFACTURING DATE AND SHELF LIFE IS 0 , THIS DATA DECIDE WHETHER 00 00 00 (YY MM DD) TO PRINT ON LABEL OR NOT TO PRINT ON LABEL. DATA 0 MAKE MANUFACTURING DATE PRINT 00 00 00. DATA 1 MAKE MANUFACTURING DATE NO PRINT. 69) FUN. 092; WHEN KEY LOCK IS LOST, THIS SOFT KEY IS VERY USEFUL TO CONVERT THE WEIGHING INTO PROGRAMMING MODE AND VICE VERSA. AFTER ENTERING PASSWORD, INPUT DAT 1. THE MODE IS CONVERTED AS THE PROGRAMMING MODE BECOMES WEIGHING MODE AND THE WEIGHING MODE BECOMES PROGRAMMING MODE. IN NORMAL OPERATION , BY DEPRESSING WITH SHIFT KEY, THE WEIGHING MODE BECOMES PROGRAMMING MODE. 70) FUN. 093; TO RETRIEVE A B C REPORT BY AUTO OR MANUAL PRESETTING DATA. DATA 0 MAKES THE ABC REPORT RETRIEVED BY MANUAL OPERATION. DATA 1 MAKES THE REPORT RETRIEVED AUTOMATICALY. 71) FUN. 094; ABC REPORT BY WEIGHT PRESETTING DATA PROGRAMMING. EX. BY ENTERING DATA 1030, THE PRESENT PLU DATA IS DIVIDED INTO 3 GROUP. FIRST TOP 10% IS A GROUP. THE SECOND 30 % IS B GROUP AND THE LAST 60% BECOMES C GROUP. BY DEPRESSING ENTER KEY, PLU NUMBER, ORDER, GROUP, WEIGHT IS DISPLAYED ON WINDOW AND THE EACH CONTENTS IS ALSO ISSUED BY LABEL. AFTER ISSUANCE OF ABC REPORT THE FUNCTION MODE IS ADVANCED TO NEXT FUNCTION MODE AUTOMATICALY. 72) FUN. 095; THE USER CAN APPLY THE PASSWORD TO THE DESIRED FUNCTION NUMBER. THE DATA IS COMPOSED BY FOUR DIGIT. THE FIRST THREE DIGIT IS FUNCTION NUMBER AND THE LAST ONE DIGIT DECIDE THE PASSWORD. DATA 1 IS TO ADOPT PASSWORD. DATA 0 IS NOT TO ADOPT PASSWORD. EX. DATA 098 1 098 IS FUNC NUMBER AND 1 IS DATA TO APPLY PASSWORD TO THE FUNCTION NUMBER. DATA 090 0 098 IS FUNC NUMBER AND 0 IS DATA NOT TO APPLY PASSWORD TO THE FUNCTION NUMBER 098. NOTE: THE USER CAN NOT DECIDE THE PASSWORD OF THE SUPERVISER FUNCTION NUMBER. 73) FUN.096; HOURLY REPORT OF THE SALES RECORD PRESETTING PROGRAMM DATA. EX. IF THE USER INJPUT 0114, THE SALES RECORD IS REPORTED AT EVERY ONE HOUR FROM 01 OCLOCK. 74) FUN.097; GROUP REPORT OF THE SALES RECORD PRESETTING PROGERAMM. IF THE USER INPUT 20, THE GROUP SALES RECORD IS REPORTED FROM GROUP NUMBER 20. THE LABEL IS ISSUED UNTIL GROUP NUMBER IS REACHED 20 AND THE MODE IS ADVANCED TO THE NEXT FUNCTION MODE. 75) FUN.098; PLU REPORT OF THE SALES RECORD PRESETTING PROGRAMM. EX. IF THE USER INPUT 0001 0020, THE TOTAL WEIGHT AND TOTAL AMOUNT IS DISPLAYED ON WINDOW FROM PLU NUMBER 1 TO 20. THE SALES RECORD LABEL IS ISSUED UNTIL PLU NUMBER BECOME 20. THE MODE IS ADVANCED TO THE NEXT FUNCTION MODE AUTOMATICALY. 76) FUN.099; ABC REPORT OF PRICE PRESETTING PROGRAMM. DATA ENTERING METHOD IS SAME AS FDUNCTION 94 PROGRAMMING MODE. NOTE: FUNC 94,96,97,98,99 ARE APPLIED TO THE AUTO /MANUAL FUNC 93. 77) FUN.100 THIS FUNCTION PROGRAMMING NUMBER IS USED TO PRESET THE UNIT PRICE PER WEIGHT DIGIT. DATA RANGE: 0,1,2,3 THE DATA 0 MAKE THE UNIT PRICE PER 1 g THA DATA 1 MAKE THE UNIT PRICE PER 10g THE DATA 2 MAKE THE UNIT PRICE PER 100g THE DATA 3 MAKE THE UNIT PRICE PER 1000 g (1) PLACE KEY LOCK TO THE PROG.POSITION (2) ENTER ON/ZERO KEY (3) F 000 UP.WT 0000 DISPLAYED (4) INPUT DATA BY DIGIT KEY TO PRESET UNIT PRICE DIGIT NUMBER AS DESIRED. IF THIS DIGIT IS PROGRAMMED IN THIS FUNCTION, THE DIGIT OF UNIT PRICE per WEIGHT IS AUTOMATICCALLY DECIDED, WHEN NORMAL WEIGHING OPERATION WORKED. (5) ENTER TO STORE THE DATA. (6) PRESS FUNCTION KEY(ON/ZERO) FOR NEXT FUNCTION PROGRAMMING. WHENEVER IS PRESSED ONE BY ONE, THE NEXT FUNCTION PROGRAMMING STEP NO. IS DISPLAYED. THE FUNCTION NUMBER IS ADVANCED TO THE NEXT FUNCNTION NUMBER. TO RECALL THE FORMER NUMBER, PRESS (FUNCTION KEY) WITH SHIFT KEY. NOTE: REPEAT STEP 1 TO 6 TO FURTHER PROGRAMMIMG . 78) FUN.101; PRICE ROUNDING PROGRAAMING DATA. THIS FUNCTION IS RELATED WITH FUN.2 DATA RANGE 0,1 DATA O IS USED TO ROUND UP DATA 1 IS USED TO ROUND OFF 79) FUN.102 PRICE DIGIT NUMBER PRESETTING PROGRAMMING DATA. DATA RANGE : 0,1,2,3. DATA 0 MAKE THE PRICE DIGIT TO DISPLAY 1. DATA 1 MAKE THE PRICE DIGIT TO DISPLAY 10. DATA 2 MAKE THE PRICE DIDGIT TO DISPLAY 100. DATA 3 MAKE THE PRICE DIGIT TO DISPLAY 1000. 80) FUN.103 PLU NUMBER PRESETTING PROGRAMMING DATA PRESETING RANGE IS 0 TO 999 80) FUN.104 LIBRARY NUMBER PRESETTING PROGRAMM PRESETTING RANGE; THIS CAPACITY IS DEPENDDING ON THE NUMBER OF CHARATER. IF 10 BYTES( ENGLISH 10 CHARACTER, KOREAN CHARACTER 5) IS COMPOSED IN ONE LIBRARY , THE PRESETTING NUMBER IS 1000 ITEM NAME. 81) FUN.105 UNIT PRICE DIGIT NUMBER PRESETTING PROGRAMM PRESETTING RANGE IS 5 DIGIT. 82) FUN.106 PRICE DIGIT NUMBER PRESETTING PROGRAMMING DATA. THERE ARE TWO KINDS TO PRESET PRICE DIGIT. THE ONE IS NOT TO PRINT BARCODE. PRESETTING RANGE IS 6 DIGIT NUMBER. THE PRESETTING DIGIT SHOULD BE ENTERED AS" 16". . THE FIRST 1 MEANS THAT THIS FUNCTION IS PRESET WITHOUT BARCODE. THE ANOTHER IS TO PRINT BARCODE. PRESETTING RANGE IS DECIDED WITH THE CONJUNCTION OF FUNC 44. IF FUNC 44 IS 00,02,04,06, 10,12,14,16, THE PRESETTING RANGE IS 5 DIGIT. IN THIS CASE THE DATA SHOLUD BE ENTERED AS" 05. THIS MEANS THE FIRST 0 MEANS THE PRESETTING DATA WITH BARCODE. IF FUNC 44 IS 01,03,05,07,11,13,15,17 THE PRESETTING RANGE IS 4 DIGIT. THE PRESETTING DATA SHOULD BE ENTERED AS 04. THE FIRST 0 IS SAME MEANING THAT PRESET WITH BAR CODE. 83) FUN.107 PLU DIGIT NUMBER PRESSETING PROGRAMING DATA PRESETTING RANGE IS 4 DIGIT. 84) FUN.108 TARE WEIGHT DIGIT NUMBER PRESETTING PROGRAMMING DATA. PRESETTING RANGE IS 5 DIGIT 85) FUN.109 SHELF LIFE PRSETTING PROGRAMMING DATA PRESETTING RANGE IS 9999 DAYS. 86) FUN. 110 - FUN. 113 THIS PRESETTING DATA IS ONLY FOR SUPERVISOR. 87) FUN. 114 SCALE CAPACITY PRESETTING DATA INPUT SCALE CAPACITY BY GRAM UNIT WITHIN THE LOAD CELL CAPACITY ALLOWANCE. IF THE SCALE WEIGH OVER THAN THIS PRESETTING DATA, THE SCALE DISPLAY "OL" SIGN. 88) FUN. 115 SCALE CAPACITY RANGE PRESETTING DATA DATA 0: MONO RANGE 1: DUAL RANGE 2: MULTIPLE RANGE 89) FUN.116 MINIMUM GRADUATION PRESETTING DATA DATA RANGE: 0,1,2,3,4,5,6,7,8,9,. DATA 0 IS 1 g DATA 1 IS 2 g DATA 2 IS 5 g DATA 3 IS 10 g DATA 4 IS 20 g DATA 5 IS 50 g DATA 6 IS 100 g DATA 7 IS 200 g DATA 8 IS 500 g DATA 9 IS 1000 g 90) FUN.117; MAXIMUM SCALE CA[PACITY PRESTTING DATA PRESETING RANGE IS SASME AS ABOVE. 91) FUN. 118 PLU TOTAL PROGRAMMING DATA DATA RANGE:0,1 DATA 1 MAKES PLU TOTAL OF WEIGHT, PRICE. DATA 2 DO NOT MAKES THE PLU TOTAL OF WEIGHT , PRICE. 92) FUN.119 - FUN. 121 SUPERVISOR PRESETTING DATA 93) FUN. 122 THE SHEET NUMBER OF LABEL ISSUANCE PRESETTING PROGRAM. PRESETTING RANGE: 1 TO 99 SHEET EX. IF 99 IS ENTERED, EACH LABEL IS ISSUED UNTIL 99 SHEET LABEL ISSUED. 94) FUN.123 - FUN. 124 SUPERVISOR PRESETTING DATA 95) FUN. 125 PRINTER TYPE PRESETTING DATA DATA O: LABEL PRINTER 1: JOURNAL PRINTER 96) FUN. 126- FUN. 137 SUPERVISOR PRESETTING DATA CAUTION: PASSWORD P1 IS ONLY FOR THE SUPERVISOR. PASSWORD P2 IS MANAGER'S ENTERING PASSWORD. BE CAREFUL NOT TO FORGET THE PASSWORD BUT IF FORGET THE PASSWORD, INITIALIZE AT FUNC 67 AND MEMORZE THE PASSWORD AGAIN.. ----------- THE END -----------------------------------------------